Doris - pages   heating oil suppliers
FAQ - lots of info here
heater - currently running on 28 second heating oil
Isolator by main van isolator - fuse for heater is in the box that covers the main isolator

to prime pump hold down the bottom 2 buttons - then arrow up -

to put into temp mode hold top right and left buttons down together - if taken out of this mode and put in frequency mode hz can be set - this sets the pump dose rate (the fan is automatically linked )
to pair remote have screen on temp - press and hold arrow up (5 sec) then press on - on remote the heater should start

Pump now located under the bonnet - seems to work well -

Eberspacher heater plugs part number E100 251384010002